Specifications
SiUS12-928_A Check
Service Diagnosis 152
6.1.4 Thermistor Resistance Check
Check No.06 Disconnect the connectors of the thermistors from the PCB, and measure the resistance of each
thermistor using tester.
The relationship between normal temperature and resistance is shown in the graph and the table
below.
For the models in which the thermistor is directly mounted on the PCB, disconnect the
connector for the PCB and measure.
Thermistor R25°C (77°F) = 20 kΩ
B = 3950
Temperature (°C / °F)
–20 / –4 211.0 (kΩ)
–15 / 5 150.0
–10 / 14 116.5
–5 / 23 88.0
0 / 32 67.2
5 / 41 51.9
10 / 50 40.0
15 / 59 31.8
20 / 68 25.0
25 / 77 20.0
30 / 86 16.0
35 / 95 13.0
40 / 104 10.6
45 / 113 8.7
50 / 122 7.2
(R9870)
()
5325986113
(˚C)
(˚F)
Tester
Resistance range
(R11906)
RTH1
Tester
(R3460)