Specifications
Check SiUS12-928_A
157 Service Diagnosis
6.1.12 Main Circuit Electrolytic Capacitor Check
Check No.14 Never touch any live parts for at least 10 minutes after turning off the circuit breaker.
If unavoidably necessary to touch a live part, make sure there is no DC voltage using the tester.
Check the continuity with the tester. Reverse the pins and make sure there is continuity.
6.1.13 Rotating Pulse Input on the Outdoor Unit PCB Check
Check No.15 <Outdoor fan motor>
Make sure that the voltage of 320 ± 30 V is applied.
1. Set operation off and power off. Disconnect the connector S70.
2. Check that the voltage between the pins 4 - 7 is 320 VDC.
3. Check that the control voltage between the pins 3 - 4 is 15 VDC.
4. Check that the rotation command voltage between the pins 2 - 4 is 0 ~ 15 VDC.
5. Keep operation off and power off. Connect the connector S70.
6. Check whether 2 pulses (0 ~ 15 VDC) are output at the pins 1 - 4 when the fan motor is rotated
1 turn by hand.
When the fuse is melted, check the outdoor fan motor for proper function.
If NG in step 2 → Defective PCB → Replace the PCB.
If NG in step 4 → Defective Hall IC → Replace the outdoor fan motor.
If OK in both steps 2 and 4 → Replace the PCB.
1
2
3
4
5
6
7
Actual rotating pulse output (0-15V)
15V
320VDC
Rotation command pulse input (0-15V)
S70
PCB