Specifications

Main Functions SiUS12-928_A
39 Function and Control
1.11 Inverter POWERFUL Operation
Outline In order to maximize the benefits of the cooling and heating capacity, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail When POWERFUL button is pressed, the fan speed and target temperature are converted to the
following states for 20 minutes.
Ex.) : POWERFUL operation in cooling mode.
Operation mode Fan speed Target temperature
COOL H tap + 90 rpm 18°C (64°F)
DRY Dry rotating speed +
50 rpm
Lowered by 2°C (3.6°F)
HEAT H tap + 90 rpm 30°C (86°F)
FAN H tap + 90 rpm
AUTO Same as cooling /
heating in POWERFUL
operation
The target temperature is
kept unchanged.
(R12294)
Target temp.
Fan
90 rpm
18˚C (64˚F)
POWERFUL ON
POWERFUL OFF
H tap
Set tap
It should be the lower limit of cooling temperature.
It counts 20 min. also in the remote controller.
20 minutes
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.