User`s manual
25
26
Cooling only use
Options
System configurations
Indoor units
Outdoor units
No.
1
2
Item
Air direction adjustment grille
Drain plug
3MXS52E 3MKS58E 3MXS68E 3MKS75E 4MXS80E 4MKS90E
No.
1
2
3
4
5
6
7
8
9
10
5-room centralised controller*
1
Wiring adaptor for time clock/remote controller*
2
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*
3
Photocatalytic deodourising filter with frame*
4
Photocatalytic deodourising filter without frame*
4
Air-purifying filter with frame*
5
Air-purifying filter without frame*
5
Remote controller loss prevention chain
Suction grille
Insulation kit for high humidity
FTK(X)S50-71F
C(F)DK(X)S25-50C
C(F)DK(X)S60C
KRC72
KRP413A1S
KKF917A4
FTK(X)S20-35
KAF970A46 KAF952B42
—
—
—
—
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
No.
1
2
3
4
Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor for DIII-NET use
DCS302CA61
DCS301BA61
DST301BA61
KRP928B2S
Note: * A wiring adaptor (KRP928B2S) is also required for each indoor unit.
KPW945A4
Wall-mounted type
Wall-mounted type
Duct-connected type
Floor-standing
type
Floor/ceiling-
suspended dual type
Duct-connected type Floor-standing type
Floor/ceiling-suspended dual type
Item
— —
— —
—
KDGF19A45
KDT25N50KDT25N32 KDT25N63
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 1 piece for 1 unit.
5-room centralised
controller
KRC72
Remote controller loss
prevention chain
KKF917A4
Air direction adjustment grille
KPW945A4
Drain plug
KKP937A4
Central remote controller
DCS302CA61
Unified on/off controller
DCS301BA61
Schedule timer
DST301BA61
Item
Decoration panel
Fresh air intake kit
Sealing member for air discharge outlet
Panel spacer
Wiring adaptor for electrical appendices*
2
Installation box for adaptor PCB
Replacement long-life filter
Remote controller
Wired type*
1
Heat pump use
Wireless type
Remote sensor
Adaptor for wiring*
2
Notes:
*1. Wiring for wired remote controller should be obtained locally.
*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
KDDQ44XA60
KDBH44BA60
KDBQ44B60A
KRP4AA53
KRP1BA57
KRP1BA101
KRCS01-1A
BYFQ60B7W1
KAFQ441BA60
BRC1C61
BRC7E530W7
BRC1E531W7
600 x 600 multi flow ceiling-mounted cassette type
1
3
2
4
5
6
7
8
9
10
No.
CDK(X)S25/35EA
Titanium apatite photocatalytic
air-purifying filter
KAF970A46
Direct installation type
Indoor units
Floor/ceiling-suspended dual type
FLXS25BVMA
7.6 (268)
9.2 (325)
37/31/28
37/31/29
FLXS35BVMA
8.6 (304)
9.8 (346)
38/32/29
39/33/30
FLXS50BVMA
11.4 (402)
12.1 (427)
47/39/36
46/35/33
FLXS60BVMA
12.0 (424)
12.8 (452)
48/41/39
47/37/34
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
Liquid (flare)
Gas (flare)
Drain
Cooling
Heating
m
3
/min
(cfm)
dB (A)
mm
kg
mm
ø12.7
16
ø9.5
17
1 phase, 230 V, 50 Hz
Almond white
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
ø6.4
ø18.0
Both liquid and gas pipes
Model name
Power supply
Front grille colour
Airflow rates
(H)
Sound levels
(H/L/SL)
Fan speed
Temperature control
Dimensions
(H x W x D)
Machine weight
Piping
connections
Heat insulation
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27
°
CDB,19
°
CWB; outdoor temp. 35
°
CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20
°
CDB,19
°
CWB; outdoor temp. 7
°
CDB, 6
°
CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. During operation these values are somewhat higher owing to
ambient conditions.
600 x 600 multi flow ceiling-mounted cassette type
Floor-standing type
FVXS35BVMA
8.3 (293)
9.2 (325)
39/27/24
39/26/23
ø9.5
FVXS50BVMA
10.8 (381)
13.2 (466)
44/36/33
45/36/33
ø12.7
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
m
3
/min
(cfm)
dB (A)
mm
kg
mm
1 phase, 230 V, 50 Hz
Almond white
5 steps, quiet and automatic
Microcomputer control
600 x 650 x195
13
ø6.4
ø20.0
Both liquid and gas pipes
Model name
Power supply
Front grille colour
Airflow rates
(H)
Sound levels
(H/L/SL)
Fan speed
Temperature control
Dimensions
(H x W x D)
Machine weight
Piping
connections
Heat insulation
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Model name
Power supply
Airflow rates
(H)
Sound levels
(H/L)*
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping
connections
Heat insulation
m
3
/min
(cfm)
dB (A)
mm
kg
mm
mm
mm
Model
Colour
Dimensions (H x W x D)
Weight
mm
kg
Panel
(option)
FFQ35B8V1B
10.0 (353)
—
32/25
—
FFQ50B8V1B
12.0 (424)
—
36/27
—
FFQ60B8V1B
15.0 (530)
—
41/32
—
FFQ25B8V1B
9.0 (318)
—
29.5/24.5
—
FFQ35B8V1B
10.0 (353)
10.0 (353)
32/25
32/25
FFQ50B8V1B
12.0 (424)
12.0 (424)
36/27
36/27
FFQ60B8V1B
15.0 (530)
15.0 (530)
41/32
41/32
FFQ25B8V1B
9.0 (318)
9.0 (318)
29.5/24.5
29.5/24.5
Cooling only Heat pump
1 phase, 230 V, 50 Hz
2 steps
Microcomputer control
285 x 575 x 575
17.5
ø6.4
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
BYFQ60B7W1
White
2.7
ø9.5 ø12.7 ø9.5 ø12.7
55 x 700 x 700
Cooling
Heating
Duct-connected type
<
900/1,100 mm width
>
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 40 Pa for CDKS/FDXS-C. Sound level values for bottom-
suction operation can be obtained by adding 5 dB to the CDKS/FDXS-C values.
Cooling
Heating
m
3
/min
(cfm)
Model name
Power supply
Airflow rates (H)
Sound levels*
(H/L/SL)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
External static pressure
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
mm
kg
mm
mm
mm
Pa
1 phase, 220-240 V, 50 Hz/1 phase, 220 V, 60 Hz
5 steps, quiet and automatic
Microcomputer control
ø6.4
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
40
CDKS50CVMA
12.0 (424)
—
37/33/31
—
27
CDKS60CVMA
16.0 (565)
—
38/34/32
—
30
35/31/29
—
25
ø9.5
35/31/29
35/31/29
25
ø9.5
CDKS35CVMA
10.0 (353)
—
CDKS25CVMA
9.5 (335)
—
FDXS50CVMA
12.0 (424)
12.0 (424)
37/33/31
37/33/31
27
FDXS60CVMA
16.0 (565)
16.0 (565)
38/34/32
38/34/32
30
FDXS35CVMA
10.0 (353)
10.0 (353)
FDXS25CVMA
9.5 (335)
9.5 (335)
Cooling only Heat pump
200 x 900 x 620 200 x 900 x 620
200 x 1,100 x 620 200 x 1,100 x 620
ø12.7 ø12.7
Specifications Options
Notes: *1. A wiring adaptor (KRP413A1S) is also required for each indoor unit.
*2. Time clock and other devices should be obtained locally.
*3. Filter is a standard accessory. It should be replaced after approximately 3 years.
*4. The photocatalytic deodourising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months.
This accessory is only required if the original filter is damaged or lost, etc.
*5. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.