User`s manual

15
16
Cooling
only
Heat
pump
Horizontal Blow
0°
0°
L itt le fe e li n g
o f blo w in g a ir
S ettable to 5 different levels
between
0° and 35°
S ettable to 5 different levels
between 0° and 60°
S ettable to 5 different levels
between 25° and 60°
Auto-s wing
between 0° and 35°
Auto-s wing
between 0° and 60°
Auto-s wing
between 25° and 60°
Draft
prevention
setting
(Set on site)
(Set on site)
Standard
setting
Setting to
prevent
soiling of
ceiling
Conditioned air is distributed
evenly by Auto-swing
operation.
Adjustable air blow angle to
suit all room conditions.
AUTO-SWING
0°
0°
0°
25°
60°
60°
0°
35°
25°
60°
35°
60°
5 directions
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
Even for modules other than 600 x 600, no inspection
opening is required. Maintenance can be performed after
simply removing the grille, because the switchbox is built
into the unit.
T-bar grid does not need to be cut
575 mm
575 mm
700 mm
700 mm
285
mm
C
o m
p
a c
t
d
e c
o r
a
t
i
v
e
pa
ne
l
T bar
600 mm
600 mm
Ceiling panel
Spiral hub cover
At low fan s peeds , the
2.5 kW model produc es
sound of only 24.5 dB ,
and even the 6.0 kW
model as low as 32 dB .
This is due to a new
spiral hub cover that
reduces internal airflow
resistance.
Option Option
Wireless remote
controller and
signal rec eiver unit
are sold as a set.
Signal receiver unit
Wireless LCD
remote controller
Wired LCD
remote controller
Suitable for the light commercial market
5.0
kW class
FFQ50B8V1B
FFQ50B8V1B
3.5
kW class
FFQ35B8V1B
FFQ35B8V1B
2.5
kW class
FFQ25B8V1B
FFQ25B8V1B
6.0
kW class
FFQ60B8V1B
FFQ60B8V1B
FFQ25B
29.5/24. 5 dB
FFQ35B
32/25 dB
FFQ50B
36/27 dB
FFQ60B
41/32 dB
(H/L)
4-way blow
1 pattern
3-way blow
4 patterns
2-way blow
1 pattern
" " denotes piping direction. " " denotes sealing member for air discharge
outlet (option).
Note: For 3-way or 2-way blow installation, the sealing member for air
discharge outlet (option) mus t be used to c lose off the unus ed
outlet(s).
Air discharge patterns can be selected
according to installation.
Multi-Flow System
Quiet sound levels of only 24.5 dB
Two selectable temperature sensors
B oth indoor unit and wired remote c ontroller
(option) c ontain temperature sens ors. Temperature
sens ing c an be set at the unit or, to further
improve c omfort level, c loser to the target area
at the wired remote c ontrol.
*Temperature s ensor on indoor unit must be used when the air
conditioner is controlled from another room.
(Wireless remote c ontroller does not have a temperature sensor.)
The filter has sanitary, mould-resistant
Mould-resistant treatment for filter
If there is a power failure while the unit is
operating, the s ys tem will res tart in the s ame
mode when power is restored.
Auto-restart
Maintenance is not required for one year.
Long-life filter
When the filter requires cleaning, the filter
icon is displayed on the remote c ontroller.
Filter sign
Programme "Dry"
Programme Dry gives priority to reduc ing the
level of
humidity rather than room temperature.
Dehumidification is c omputer controlled to prevent
Switchable fan speed: High/Low
Unc omfortable cold air draft is not discharged
when heating operation starts or when s witching
to heat after defrosting.
Hot start (after defrost)
Note:
Operation noise
increases when
using 2-way or 3-
way blow.
Provided with condensate drain pump
750 mm
To facilitate recycling, the composition of each
plastic component is marked on the part.
Daikin's innovative air disc harge mec hanism
keeps air flow away from the ceiling. C eiling
cleaning is required less frequently.
Ceiling soiling prevention function
600 x 600 Multi Flow Ceiling-Mounted Cassette Type Indoor U nits
Low draft performance is
superior by design
Designed to fit 600 mm wide
ceiling grids perfectly
Comfortable across all areas
Product lineup Product lineup