OWNER'S MANUAL AIR CONDITIONER ONE-TWIN SPLIT TYPE Thank you very much for purchasing our air conditioner, please read this owner's manual carefully before using your air conditioner, save this manual in a safe place for future reference.
CONTENTS IMPORTANT SAFETY INFORMATION............................................................. 1 HINTS FOR ECONOMICAL OPERATION......................................................... 2 PARTS NAMES.................................................................................................. 3 NAMES AND FUNCTIONS OF INDOOR UNIT CONTROLS............................ 4 ADJUSTING AIR FLOW DIRECTION................................................................
IMPORTANT SAFETY INFORMATION CAUTION Do not attempt to install this unit yourself. This unit should be installed by qualified persons. Dangerous DANGER Do not attempt to service the unit yourself. This unit has no user serviceable components, opening or removing the cover will expose you to dangerous voltage. Turning off the power supply will not prevent potential electric shock. DANGER No Never put hands or objects into the air outlet of indoor and outdoor units.
IMPORTANT SAFETY INFORMATION NOTE For proper performance, operate the unit under the usable operating temperature and humidity conditions indicated in this owner's manual. If the unit is operated beyond these conditions, it may cause malfunctions of the unit or dew dripping from the unit. The appliance is not intended for use by children or the disables without supervision. Children should be supervised to ensure that they do not play with the appliance.
PARTS NAMES Indoor unit 4 3 5 2 6 1 11 Indoor unit 1 Room temperature sensor 2 Front panel 3 Air inlet 4 Air filter 5 Air outlet 6 Vertical air flow louver 7 Horizontal air flow grille 8 Display panel 9 Infrared signal receiver 10 Remote Controller 11 Control panel 7 8 9 10 Indoor unit 4 3 2 5 6 7 1 11 Outdoor unit 12 Drain hose, refrigerant connecting pipe and electric wiring.
NAMES AND FUNCTIONS OF INDOOR UNIT CONTROLS Control panel Lift the front panel to perform control panel settings. . . Auto/Cool Temporary operation Opening the front panel Pull up from two ends of the front panel. Open the panel and lift the panel up to an angle where it remains fixed. Do not lift the panel any further when it stops with a clicking sound. Closing the front panel Lower ends of the front panel, push the ends on both sides. Close the panel firmly.
ADJUSTING AIR FLOW DIRECTION To automatically swing the air flow direction Perform this function while the air conditioner is in operation. Push the SWING button on the remote controller. To stop the function, push the SWING button again. To change the swing direction, push the AIR DIRECTION button. .. CAUTIONS The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the ON TIMER is set).
HOW THE AIR CONDITIONER WORKS . AUTOMATIC OPERATION Operation suppression zone Operation starts ¡£ 1 C . . ¡ £ 2 C 1 hours Set temperature 2 hours ECONOMIC Operation Cooling Fan only Cooling Room temperature The air conditioner selects and operates in one of the operating modes of cooling, heating (cooling only type without) or fan only, depending on the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you.
MAINTENANCE WARNING WARNING Before you clean the air conditioner, be sure to disconnect the power supply plug. Cleaning the indoor unit and the remote controller Use a dry cloth to wipe Thinner Select fan only mode CAUTIONS Use a dry cloth to wipe the indoor unit and remote controller. A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Never use a damp cloth on the remote controller.
MAINTENANCE 3. Take hold of the handles and pull the air filter downward. 4. Remove the AIR FILTER from the indoor unit. Clean the AIR FILTER once two weeks. Clean the AIR FILTER with a vacuum clearer or water, then dry it up in cool place. 5. Remove the ACTIVE CARBON FILTER/ELECTRO STATIC FILTER from the indoor unit and take it out from its support frame.
AIR CONDITIONER OPERATIONS AND PERFORMANCE Three-minute protection feature A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation. This will protect the machine. (cooling only type without) Heating characteristics preheating operation The air conditioner will not deliver warm air immediately after it is started. Warm air flows out after approximately 5 minutes when the indoor heat exchanger warms up.
INSTALLATION Location: In cooling operation, the air conditioner will dry the room air, so please fix a pipe to drain all the water away in the air conditioner. Please let the indoor unit away from the TV set and the radio more than one meter in order to avoid the picture and noise interference. Powerful radio transmitters or any other devices radiating high frequency radio waves can cause the air conditioner to malfunction.
TROUBLES AND CAUSES Before you ask servicing or repairs, check the following points. The unit cannot operate Recheck Inoperative Does not cool or heat well. The air inlet or outlet of the outdoor unit is blocked. Doors or windows are open. The air filter is clogged with dust. The louver is not at the correct position. The fan speed is set to low. The temperature setting is too high or too low. Room air is smelly.
TROUBLES AND CAUSES (CONCERNING REMOTE CONTROLLER) Before you ask for servicing or repairs, check the following points. Setting Change Is Impossible Causes Symptoms Check whether the MODE indicated on the display is "AUTO" AUTO The fan speed can not be changed. Check whether the MODE indicated on the display is "DRY" DRY Reason and Disposal When the automatic mode is selected, the air conditioner automatically selects the fan speed.