Service manual

MAN 650314:D
19
When SIGNAL is displayed, press and hold SW1 to enter the SIGNAL setup menu.
Release SW1 and the current setting will be displayed.
Press and release SW1 to toggle from 12V HIGH to 5V LOW.
When the desired setting is displayed, press and hold SW1 until DONE is displayed.
Release the switch to go on to the next sub-menu item.
Exit tach setup (DONE)
This will allow you to exit the tach setup and go on to the next setup menu.
When TACH DONE is displayed, press and hold SW1 until DONE is displayed
Release the switch to go on to the next menu.
VOLT SETUP
The Volt setup allows you to set a warning point that will cause the message display to
flash the voltage reading in the message display whenever the value drops below the warning
point. The low voltage point can be set from 10 -13.1 volts. There is only one thing to set in the
volt sub-menu; either WARNING or DONE will be displayed.
Press and hold SW1 while turning the key on. Release the switch. Press and release
SW1 to get to the “volt” setup menu. Press and hold the switch until volt warning is
displayed to enter the volt setup menus, then release SW1.
When WARNING is displayed, press and hold SW1 until you see VOLT WARN LOW
followed by a number. Release SW1; this is the current voltage warning point.
Press and release SW1 to increase the value from 10.0” – “13.1”.
When the desired setting is displayed, press and hold SW1 until DONE is displayed.
Release the switch to go onto VOLT DONE” Press and hold SW1 to exit “VOLT” setup
menu.
WATER TEMP SETUP
The Water Temp setup allows you to select the units the temperature is displayed in,
Fahrenheit or Celsius. It also allows you to set a high temperature warning point that will cause
the message display to flash the water temperature reading whenever the value is higher than the
set point. There is also a test mode that will display the resistance for the sensor for trouble
shooting assistance.
Press and hold SW1 while turning the key on. Release the switch. Press and release
SW1 to get to the “water” setup menu. Press and hold the switch until “water sender” is
displayed to enter the water setup menus, then release SW1.
Now you can press and release the switch to scroll through the water sub-menus,
SENDERWARNing” “test” “DONE”. When you get to the desired sub-menu press and hold the
switch to select it.
Temp sensor setup (SENDER)
This menu is used to set the temp sensor type. Dakota Digital only offers one temp sensor
for this system, it is SEN-04-5, 100-300 F(40-150 C), 1/8” NPT threads. You can use bushings to
adapt the sensor to various locations. You will select “DD F” to read in Fahrenheit, or select “DD
C” to read in Celsius.
You can also read the temp with the use of a bus interface module (BIM). Dakota Digital
offers the BIM-01-1 that will allow you to read the engine temp signal from an ECU if you are
installing the system in a vehicle equipped with an OBDII diagnostic port or a drive train from a
newer vehicle. Most 1996 and newer vehicles have this. You will select “BUS F” to read in
Fahrenheit, or select “BUS C” to read in Celsius.