Installation Manual

MAN 650314:J
14
SETTING UP THE CONTROL BOX
Below is the list of setup menus. You must have SW1 wired to enter setup, SW2 will be
used in some menus as well; descriptions of each menu are below. Pay close attention to
Setup menus and options as incorrect settings will cause faulty readings on the displays.
Main Menu Sub Menu Description____________________
SPEED
SENDER (normal, bus) Select sensor type
AUTO Auto calibrate speed
ADJUST Adjust the speed calibration
SERVICE (OFF, 500 7500) Select the service countdown
OUTPUT (2k ppm, 4k PPm) Select output speed signal PPM setting
DONE Exit setup menu
TACH
ENGINE (bus, 1 16) Set engine cylinder count
UPDATE (slow, mid, fast) Set rpm update rate
WARN (2200 14800) Set rpm shift warning point
SIGNAL (5V LOw, 12V HIGH) Select rpm signal voltage level
DONE Exit setup menu
VOLT
WARNING (LOW 10.0 13.1) Set low volt warning point
DONE Exit setup menu
WATER
SENDER (DD F,DD C,BUS F, BUS C) Select sensor type
WARNING (150-300F / 65 -148c) Set high temp warning point
TEST Display sensor ohm reading
DONE Exit setup menu
OIL
SENDER (normal, BUS) Select sensor type
WARN (LOW 5 36) Set low pressure warning point
TEST Display sensor voltage reading
DONE Exit setup menu
FUEL
SENDER (SW 33, bus, 63 vet, Select sensor type
CUSTOM, GM 30, GM 90,
GM 250, F 10, F 150, V 180)
CUSTOM Calibrate custom fuel sensor
TEST Display sensor ohm reading
DONE Exit setup menu
LIGHTING
DIM LEVEL (ADJUST 0-31) Change preset night dimming
DAY LEVEL (ADJUST 0-32) Change day time backlighting
DONE Exit setup menu
BIM
SCAN Check/scan for connected modules
SETUP Enter setup (only when modules present)
DONE Exit setup menu
DISPLAYS
INDICATORS Enable indicators on face and LCD
(LIGHT ONLY, LIGHT+LCD)
LOCATION (1, 2, 1+2, OFF) Select display location
DONE Exit setup menu