User's Manual

22
WARNING
2 Wire the Safety Reversing Sensors
Power
1 Connect power
To prevent possible SERIOUS INJURY or DEATH from electrocution or re:
· Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE removing cover
to establish permanent wiring connection.
· Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
· NEVER use an extension cord, 2-wire adapter, or change plug in any way to make it t outlet. Be sure the
opener is grounded.
1.1 Install the sensors to the mounting
bracket using the screws.
1.2 Position the mounting
b
racket against the wall
with the curved arms facing the door. Make sure
there is enough clearance for the beam to be
unobstructed. Attach the mounting bracket to the
wall using lag screws.
Mounting Bracket
Not provided
No more than 15cm
2.1 Strip 7/16 inch (11 mm) of insulation from
each set of wires. Separate the wires. Twist the
white wires together. Twist the white/black wires
together.
2.2 Insert the white wires into the
#1 terminal on the garage door
opener. Insert the white/black wires
into the #2 terminal on the garage door
opener.