User's Manual

23
To avoid installation difculties, do not activate the garage door opener at this
time. To reduce the risk of electric shock, your garage door opener has a grounding
type plug with a third grounding pin. This plug will only t into a grounding type
outlet. If the plug doesn’t t into your outlet, contact a qualied electrician to install the
proper outlet.
THERE ARE TWO OPTIONS FOR CONNECTING POWER:
Option A TYPICAL WIRING
1.1A Plug in the garage door opener into a grounded outlet.
1.2A DO NOT run garage door opener at this time.
Option B PERMANENT WIRING
If permanent wiring is required by your local code, refer to the following procedure.
To make a permanent connection through the 7/8" hole in the top of the motor unit (according to local code):
1.1B Be sure power is NOT connected to the opener, and disconnect power to circuit.
1.2B Remove the garage door opener cover and set aside.
1.3B Remove the attached green ground terminal.
1.4B Cut black and white wires and strip away 1/2" (1 cm) of insulation, 6" (15 cm) before spade terminals.
1.5B Remove the power cord from opener.
1.6B Knock out the hole plugs above 7/8"hole.
1.7B Install a conduit or ex cable adapter to the 7/8" hole
1.8B Run wires through conduit, cut to proper length and strip insulation.
1.9B Attach with wire nuts provided. Attach the ground wire to the green ground screw.
The opener must be grounded.
1.10B Properly secure wire under plastic ties so that wire does not come in contact with moving parts.
1.11B Reinstall the cover. DO NOT run garage door opener at this time.
2 Ensure the Safety Reversing Sensors are aligned
The door will not close if the sensors have not been installed and aligned correctly
When the light beam is obstructed or misaligned while the door is closing, the door will reverse and the garage door
opener lights will ash three minutes. If the door is already open, it will not close.
RED
G
REE
N
LED