User`s manual
52 Preliminary Pantera TF 1M60 and 1M30 User’s Manual
DALSA 03-32-10033-08
Binning (HxV)
Symbol 1 x 1
2 x 1
4 x 1
8 x 1
1 x 2
2 x 2
4 x 2
8 x 2
1 x 4
2 x 4
4 x 4
8 x 4
1 x 8
2 x 8
4 x 8
8 x 8
tTRANSFER (time from
falling edge of EXSYNC to
start of readout in SMART
SYNC, pretrigger=0)
1.339 ms 1.339 ms 1.339 ms 1.339 ms
tREADOUT (frame
readout time, pretrigger=0)
15.3856 ms 8.5112 ms 4.941 ms 3.136 ms
tOVERHEAD (time
after readout before next
EXSYNC)
1.6 µs 1.6 µs 1.6 µs 1.6 µs
TwSYNC_INT (min
integration pulse, not
SMART SYNC)
15.025 µs 16.35 µs 19.3 µs 24.5 µs
TwSYNC_INT (min
integration pulse, in SMART
SYNC)
15.025 µs 16.35 µs 19.3 µs 24.5 µs
tFRAME PERIOD
(min frame period)
16.725 ms 9.7102 ms 6.2798 ms 4.475 ms
tFL (time from FVAL to
first LVAL)
2.225 µs 3.55 µs 6.125 µs 11.325 µs
tLINE (LVAL high time)
12.8 µs 12.8 µs 12.8 µs 12.8 µs
tLVAL_LOW (LVAL
low time)
2.225 µs 3.55 µs 6.5 µs 11.7 µs
tLF (time from last LVAL
to end of FVAL)
0 ns 0 ns 375 ns 375 ns
Camera Link™ Configuration Table
The following table provides tap reconstruction information. DALSA is working with the
machine vision industry to use this table as the basis for auto configuration. Visit the
http://vfm.dalsa.com Web site and view the DALSA Camera Link Implementation Road
Map document, 03-32-00450, for further details.
Pantera TF 1M60 and 1M30 Interface Parameters
Table 19: Frame Grabber Interface Parameters (Unverified)
Item (when programmable configuration the
options are separated with a | )
1M60 1M30
Imager Dimension <1,2 or 1|2> 2 2
Imager Columns<number of active columns, X> 1024 1024
Imager Rows<number of active rows, Y> Line Scan/TDI
are defined as 1
1024 1024
Number of Imager Taps <1,2,3…..> 2 1