DALSA 03-32-10033-08
Command Syntax Parameters Description
set video mode
svm i
Set video mode. Available values are:
0: Normal operating mode
1: Test pattern Left side (1M60 only)
2: Test pattern Right side (1M60 only)
3: Test pattern Both sides
4: Flip image Left side (1M60 only)
5: Flip image Left side Test pattern Left side
(1M60 only)
6: Flip image Left side Test pattern Right
side
(1M60 only)
7: Flip image Left side Test pattern Both
sides
(1M60 only)
8: Flip image Right side
(1M60 only)
9: Flip image Right side Test pattern Left
side
(1M60 only)
10:Flip image Right side Test pattern Right
side
(1M60 only)
11:Flip image Right side Test pattern Both
sides
(1M60 only)
12:Flip image Both sides
13:Flip image Both sides Test pattern Left
side
(1M60 only)
14:Flip imgae Both sides Test pattern Right
side
(1M60 only)
15:Flip image Both sides Test pattern Both
sides
write user
settings
wus
Write all of the user settings to EEROM
verify
temperature
vt
Displays the temperature of the digitizer
board and the sensor board. Condition <0ºC
or >85ºC will produce an error condition.
B2 Error Messages
Code Description Suggested Cause
0 SUCCESS Command executed without major
error detected
3 Invalid command Command not recognized
4 Command parameters incorrect or
out of range
Command parameters are invalid or
out of range
Parameters:
i = integer
f = float
t = tap