Setup History
a. Click the “History” button in the “Setup Communications and Outputs” panel.
The Status and Configuration panel changes to provide options for saving data to the BOA (his-
tory log) or saving images to the client PC (image log).
Enable
Enable
Image
History
Log
Logging
History Setup Panel
Enabling the History Log saves images and data for Pass, Recycle and Reject; to the BOA
memory. You can look at these from the Monitor panel, when the inspection is running.
Image Log to file – saves camera images (also called ”image logging”) to the Client PC, BOA
“server” memory, or any mapped drive, when the Solution is running.
The number field is the maximum number of images. Images are saved to file names with se-
quential numbers (image0.bmp, image1.bmp). The counter wraps at this number, and continues
to overwrite older images until you disable image logging.
1. Check the Enable box.
2. Enter a maximum number of images to save (in each category or folder).
3. Select a category (Pass/Recycle/Reject).
4. If you select more than one category, select “SubFolders” to create sub-directories for Pass,
Recycle and Reject.
5. Check the Graphics box if you want measurement graphics saved. If the box is clear, only
the camera image is saved.
6. Check the Multi Cam box to save each selected camera’s image to a different file name
(image0.bmp, image0_1.bmp, image0_2.bmp). If the Multi–cam check box is clear, only
the active camera image is saved. Use the Camera check boxes to select which cameras to
save images for (or all 3).
7. Select Client (PC) or Server (Vision System). This is where the images are saved.
8. Change the file name if desired (default is ”Image”).