User`s manual
405-00026-00iNspect Express User’s Manual
106 Rev 1600; 12 July 2010
reset # reset the production line with a specific number of parts between the two sensors.
reset Statistics reset the counters for Pass/Recycle/Reject.
saves ## Desc saves the current Solution, using the ID number and string description given.
gtol get tolerances for all measurements.
stol measName camID minRecycle minPass Perfect MaxPass MaxRecycle set tolerances
for the specified measurement.
autosave [On|OFF] turn on/off saving the edited solution file when exiting iNspect Express. .
export FullPathFileName ## export the Solution at ID ## to the specified path and name.
import FullPathFileName ## import the specified Solution file and store at Solution ID ##.
Solution Summary Report
A utility creates an HTML document that gives details of cameras, tools and tolerances, func-
tions, and variables defined in a Solution. This report may be useful in documenting your tests
and software. This report is not intended to recreate a Solution file.
This utility reads the currently loaded Solution file.
1. Click the “Select Solution” button in the main panel or in the Run/Monitor panel.
2. Use the menu to define where to save the report file and Template image. You can also
change the file name.
3. Click the “Generate Report” button. You will be warned before overwriting an existing file.
You will be prompted to view the resulting report file.
If you copy the report file to another location, you must copy the template image to the same
directory location. The HTML file points to the JPEG image file.
NOTE This report includes an image (without graphics) of the Template image you
used to draw or train tools. This report does not contain an image of the tools
drawn on the image. Therefore, tool placement is not documented. You can use
image logging to save images with graphics.