Configuration Changes
On the Vision System Home page in Internet Explorer, there is a link for the “Application Setup”.
The Vision System Home Page
Configuration Page
Recycle Enable: If you do not have Recycle tolerances and Failure tolerances, you can clear this
checkbox to hide the Recycle tolerances in the tool properties.
Auto Load Solution Enable: Clear the checkbox to disable loading a Solution when power is
applied to the BOA. Or, you can enter a Solution number to load when power is applied.
Template Solution Enable: select this option to load your saved “Template” solution when
“Start New Solution” is clicked.
Image Region of Interest: reduces the image size (Crop) and the amount of image data acquired
and processed. This also reduces the data sent to the Monitor.
The BOA vision system will reboot when you click the “Apply Configure” button to accept your
changes. Click the “Home” button if you have not made changes.