User`s manual

405-00026-00iNspect Express User’s Manual
116 Rev 1600; 12 July 2010
4. Click on the Locator button. In the Configuration and Status panel, select Locator 1, and
select “Set position anchor”.
5. Click on the Center point of the Match Tool.
6. Select the Edge Count tool and select a Circle Region.
7. Draw a circle on the disk, near the outer edge and passing through the notch. Move and re-
size the circle as needed.
Loc1
Locator 1 and Edge Count Tool
8. Right-click on the Edge Count tool, to open the Properties. Check the box beside “Activate
edge points”. Close the Properties box.
9. Click the Locator button. In the Configuration and Status panel, select Locator 2.
10. Select “Set position anchor” and click on the center point of the Match Tool.
11. Select “Set rotation anchor” and click on the active point at the left edge of the notch.
“Rotation anchor”.
Loc2
2
Locator 2 Anchors – Match Tool and Edge Count Tool
In this example, we need Locator 1 to find the center circle first, to accurately place the edge count
tool before Locator 2 tries to track the rotation. Locator 2 needs two anchor points to track rota-
tion. You can use Locator 2 for all other tools added to this inspection.