User`s manual

405-00026-00iNspect Express User’s Manual
122 Rev 1600; 12 July 2010
5. Set the time interval (30 ms) for the Periodic function and then click the “Add” button.
The Periodic Function now appears in the Function list. The Periodic Function will occur at the
interval entered (30 ms). To prevent multiple inspections per trigger a variable called “Once”, in
this example, is set after one trigger is generated and will be reset after the image is processed.