User`s manual
405-00026-00iNspect Express User’s Manual
32 Rev 1600; 12 July 2010
edge find direction
Rotate
Handle
Resize
Handle
Point Properties
Position variation in either horizontal or vertical position, relative to the original or
“trained” position. Units are in Calibrated units, or in pixels if Calibration was
not performed or the axis origin was reset to a corner of the image area.
X horizontal position or coordinate, relative to the Origin. Units are in Calibrated
units, or in pixels if Calibration was not performed or the axis origin was reset to
a corner of the image area.
Y vertical position or coordinate, relative to the Origin. Units are in Calibrated
units, or in pixels if Calibration was not performed or the axis origin was reset to
a corner of the image area.
• Enable – check this box to report a measurement and pass or fail the part on this measurement;
or clear this box to not report a measurement and not pass or fail the part on this measurement.
• Relative – clear the box to report actual numbers; check the box to report difference.
• Auto label position – puts the label (PP1, PP2) beside the Point in the display. Clear the check
box to move the label to another location (or with the Properties box closed, drag the label).
• Locator – makes the tool follow the Locator, and follow the part. Select a locator (by number)
to follow, or select “X” to disconnect the tool from the locator, or make the tool stay in a fixed
position in the image area.
• Accuracy – number of sample points used to find the edge, indicated by the pink dots.
• Edge type – how to detect the edge a point is attached to. For example, if a line is more than one
pixel wide, this setting can produce different results. Strongest use the strongest edge found in
the search area, First use the first edge found in the search direction, Last use the last edge
found in the search direction.