User`s manual
iNspect Express User’s Manual405-00026-00
37Rev 1600; 12 July 2010
• Locator – makes the tool follow the Locator, and follow the part. Select a locator (by number)
to follow, or select “X” to disconnect the tool from the locator, or make the tool stay in a fixed
position in the image area.
• Lines – the number of ruler lines in the rake; number of measurements or samples.
g. Click on the ruler button 
 in the Rake Properties box, to set new units (Scale) on this
one measurement, or on the whole coordinate system used for this camera view.
NOTE If you enter new units, and select “Coordinate System”, clicking the green
“check” in the scale properties immediately applies the changes to the whole
coordinate system; clicking the red X button in the Distance Properties does not
undo the change to the coordinate system. Click the curved arrow button 
 to
undo scale changes and revert to pixel coordinates for the whole coordinate sys-
tem. This removes Calibration.
Scale Properties
h. Click on the “check” button   to accept changes and close the Scale box. Click on the red
X button 
 to close without changes. Click the arrow button to undo scale and calibration.
i. In the Rake Properties box, click on the padlock button 
 to lock the value for “Perfect”
so it does not change as you adjust or move your measurement.
j. Click the “Preprocess” button 
 to add image filtering, or feature enhancement. Adding
preprocessing may increase inspection time. Please refer to page 15.
k. Click on the “check” button 
 to accept changes and close the Rake Properties box. Click
on the X button 
 to close without changes.