User`s manual

405-00026-00iNspect Express User’s Manual
42 Rev 1600; 12 July 2010
e. Right-click on the Region outline. A Count Properties box opens. In this box you can: re-
name the measurement, set the tolerances for recycle and reject, specify the object size or
area, change the sensitivity. A higher sensitivity is more sensitive to defects or light
changes. A zero in the maximum field for Area, major or minor axis, means there is no maxi-
mum limit. Use the tabs and “Enable” check boxes to enable measurements.
NOTE The “size” of a reflection can change greatly.
Sensitivity
Lock/unlock
“Perfect”
Vertical
Zoom
Accept
changes and
lock values
minimum
maximum
Select
Objects
reported
Lock/unlock
values
Count Properties
Count count the number of objects, blobs or artifacts in the Region.
Area measure the size (Area) of each object.
Major measure the major axis of each object.
Minor measure the minor axis of each object.
X horizontal position of the center point of each object.
Y vertical position of the center point of each object.
Enable – check this box to report a measurement and pass or fail the part on this measurement;
or clear this box to not report a measurement and not pass or fail the part on this measurement.
Relative – clear the box to report actual numbers; check the box to report difference.
Area – minimum and maximum area of objects. (”blob size”) Objects outside this range
are not counted. A zero in the maximum field means there is no maximum limit.