The Padlock button allows you to lock the Value, so it does not change while you change
parameter settings or move or resize the Region.
Code The code value read, or compare code to a fixed value.
The measurements below apply only to the DataMatrix, not PDF417 or QR–Code
Width Overall width of the maxtix. (number of cells or columns)
Height Overall height of the matrix. (number of cells or rows)
Cell Cell size. (in pixels)
Flip is the code “flipped” or “mirrored”. 1=flipped, 0=not flipped.
Category Report the category (code type). 0=unknown, 1=ECC000,
2=ECC050, 3=ECC080, 4=ECC100, 5=ECC150, 6=ECC200.
Axial Non–Uniformity
Grade
Report the axial non–uniformtiy grade. 4=GradeA, 0=GradeF.
Axial Non–Uniformity
Value
Report the calculated value used to determine the grade.
Cell Contrast Grade Report the cell contrast grade. 4=GradeA, 0=GradeF.
Cell Contrast Value Report the caclulated value used to determine the grade.
Cell Modulation Grade Report the cell modulation grade. 4=GradeA, 0=GradeF
Fixed Pattern Damage
Grade
Report the fixed pattern damage grade. 4=GradeA, 0=GradeF.
Grid Non–Uniformity
Grade
Report the grid non–uniformity grade. 4=GradeA, 0=GradeF.
Grid Non–Uniformity
Value
Report the calculated value used to determine the grade.
Min Reflectance Grade Report the minimum reflectance grade. 4=GradeA, 0=GradeF.
Min Reflectance Value Report the calculated value used to determine the grade.
Modulation Grade Report the Modulation grade. 4=GradeA, 0=GradeF.
Grade Report the Overall grade. 4=GradeA, 0=GradeF.
Print Growth Grade Report the print growth grade. 4=GradeA, 0=GradeF.
Print Growth Value Report the calculated value used to determine the grade.
Scan Grade Report hte scan grade. 4=GradeA, 0=GradeF.
Symbol Contrast Grade Report the symbol contrast grade. 4=GradeA, 0=GradeF.
Symbol Contrast Value Report the calculated value used to determine the grade.
Unused Error Correction
Grade
Report the unused error correction grade. 4=GradeA, 0=GradeF.
Unused Error Correction
Value
Report the calculated value used to determine the grade.
Auto label position – puts the label beside the Region in the display. Clear the check box to
move the label to another location (or with the Properties box closed, drag the label).