User`s manual

iNspect Express User’s Manual405-00026-00
69Rev 1600; 12 July 2010
endpoints of the first and last ruler lines define the search “area”. You can drag the solid
square to resize the ruler lines and increase the search area; but searching more area may
increase the processing time.
Complex Shapes: The spacing of samples may round the corners of more complex shapes or
simple curves, and place samples that are not centered on the edge. Zoom in and verify that the
rubber line follows the edge of your part. You can try decreasing the sample gap value, to place
more samples closer together. Or you can move individual samples by dragging the solid square
at the center of each ruler line (where the ruler line crosses the rubber line).
d. When you hover over the center line, the label turns red and a message should appear, telling
you to “Right-click to edit.”
e. Right-click on the center line. A Contour Properties edit box opens. In this box you can: set
the tolerances for recycle and reject, rename the measurement, change the sensitivity and
sample gap (space between ruler lines, and the number of sampling lines around the edge).
Use the tabs and “Enable” check boxes to enable or disable measurements. By default two
measurements are enabled.
Contour Properties
Deviation maximum or largest change (distance) from the trained position.
Failed sections number of samples that had a deviation larger than the allowed maximum.
Enable – check this box to report a measurement and pass or fail the part on this measurement;
or clear this box to not report a measurement and not pass or fail the part on this measurement.