User`s manual

405-00026-00iNspect Express User’s Manual
72 Rev 1600; 12 July 2010
Bead Properties
Deviation maximum or largest change (distance) from the trained position.
Failed sections number of samples that had a deviation larger than the allowed maximum.
Min width minimum measured width (edge to edge) of the bead.
Max maximum measured width (edge to edge) of the bead.
Mean average measured width of the bead.
Enable – check this box to report a measurement and pass or fail the part on this measurement;
or clear this box to not report a measurement and not pass or fail the part on this measurement.
Auto label position – puts the label (Bead1) beside the tool in the display. Clear the check box
to move the label to another location (or with the Properties box closed, drag the label).
Locator – makes the tool follow the Locator, and follow the part. Select a locator (by number)
to follow, or select “X” to disconnect the tool from the locator, or make the tool stay in a fixed
position in the image area.
Sample gap – changes the spacing between samples, and changes the number of samples.
Contrast – defines the features to look for, and the background to ignore.
Sensitivity – a higher setting finds more defects or ignores less.