Locator Panel
b. Select a Locator number, 1 through 4. All tools default to Locator 1.
c. Click on the radio button beside “Set position anchor” then click on an active point made by
a measurement tool. A ”cross hair” symbol appears, centered on the point.
d. Click on the radio button beside “Set rotation anchor” then click on a different active point
made by a measurement tool. A flag symbol appears, attached to this point.
e. Hover your cursor over one of the anchors, and right-click to open the Locator Properties.
Locator Properties
Angle rotation of the part from the position in the trained image. Measured in
degrees, with positive direction from X axis to Y axis. This direction is
dependent on the direction of the Origin (”flip Y axis” option).
Enable – check this box to report angle (rotation) measurement and pass or fail the part on this
measurement; or clear this box to not report a measurement and not pass or fail the part on this
measurement.
Relative – clear the box to report actual numbers; check the box to report difference.