User`s manual
58 Operational Reference Genie Color Series-GigE Vision Camera
Output Control via Sapera LT or GigE Vision Compliant Applications
Sapera
Genie Sapera parameters for Strobe and General Outputs.
See "Accessing Features with Sapera++ LT" on page 73.
OutputSe
lectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2, Pulse On:
Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout = 6, Pulse On: End
of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input 1 = 9, Pulse On: Input 2 =
10}
PulseDelayOutput_x = Delay in µs to assert pulse output
PulseDurationOutput_x = Pulse duration in µs
PolarityOutput_x = {Active Close = 0, Active Open = 1}
XML features for Strobe and General Outputs:
OutputLineSelector = Index to select output line {output 1 = 0, output 2 = 1}
OutputLineMode = {SoftwareDriven = 0, EventDriven = 1}
OutputLineEventSource = Event generating output line pulse {StartOfTrigger=0,
StartOfExposure=1, StartOfReadout=3, EndOfReadout=4, EndOfAcquisition=5,
EventOnInputLine1=6, EventOnInputLine2=7, OverTrigger=8,}
OutputLinePulsePolarity = State of output opto-coupler {Active Close = 0, Active Open = 1}
OutputLinePulseDelay = Delay in µs to assert pulse output (range 0 to 64k)
OutputLinePulseDuration = Pulse duration in µs (range 0 to 64k)
OutputLineValue = Static output state {Open = 0, Close = 1}