User`s manual
74 Operational Reference Genie Color Series-GigE Vision Camera
Feature Type STRING
Feature Name Acces
s
W-mode Type Value
Server Name RO Invalid STRING Genie_C1024_1 (example)
Number of Features RO Invalid STRING (number dependent on firmware version)
DeviceVendorName RO Invalid STRING DALSA
DeviceModelName RO Invalid STRING Genie C1024 (example)
DeviceVersion RO Invalid STRING 1.30.122 (example)
FirmwareVersion RO Invalid STRING 14275 (example)
DeviceID RO Invalid STRING S1234567 (example)
MACAddress RO Invalid STRING 00:01:0D:A0:F0:41 (example)
DeviceUserID RW N.acq STRING Inspection-1 (user set example)
IPAddress RO Invalid STRING 192.168.0.1 (example; R/W in Persistent IP mode)
SubnetMask RO Invalid STRING 255.255.0.0 (R/W in Persistent IP mode)
DefaultGateway RO Invalid STRING 0.0.0.0 (R/W in Persistent IP mode)
Feature Type ENUM
Feature Name Acces
s
W-mode Type Values
Interface RO Invalid ENUM GigE Vision = 0
DeviceScanType RO Invalid ENUM Area scan = 0
Linescan = 1
ColorType
(dependent on camera model)
RO Invalid ENUM Monochrome Sensor = 0
CFA Bayer Sensor GR = 1
CFA Bayer Sensor RG = 2 (current)
CFA Bayer Sensor GB = 3
CFA Bayer Sensor BG = 4
RGB Sensor = 5
ExposureMode RW N.acq ENUM Programmable = 1
Pulse Controlled = 2
ExposureAlignment RW N.acq ENUM Synchronous = 0
Reset = 1
FlatFieldFormat
(dependent on camera model)
RO N.conn ENUM Mono 8 - Unsigned = 16844800
Mono 9 - Unsigned = 16779520
Mono 10 - Unsigned = 16779776
RGB = 1124075520
ImageFlip RW ENUM Off = 0
Horizontal = 1
TestImageSelector RW Always ENUM Off = 0
Grey Horizontal Ramp = 1
Grey Vertical Ramp = 2
Grey Diagonal Ramp Moving = 3
Purity = 4
Color = 5