User`s manual
Genie Color Series-GigE Vision Camera Operational Reference 75
LUTFormat
(dependent on camera model)
RO Invalid ENUM Mono 8 – Unsigned = 16844800
Mono 8 – Signed = 285280256
Mono 9 – Unsigned = 16779520
Mono 9 – Signed = 285214976
Mono 10 – Unsigned = 16779776
Mono 10 – Signed = 285215232
RGB = 1124075520 (color Genie)
TriggerSource RW N.acq ENUM Input 1 = 0
Input 2 = 1
Software = 2
OutputSelectorOutput_1 RW Always ENUM Open = 0
Close = 1
Strobe On: Start of Exposure = 2
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10
OutputSelectorOutput_2 RW Always ENUM Open = 0
Close = 1
Pulse On: End of Exposure = 3
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10
PolarityInput_1 RW Always ENUM Active High = 0
Active Low = 1
PolarityInput_2 RW Always ENUM Active High = 0
Active Low = 1
PolarityOutput_1 RW Always ENUM Active Close = 0
Active Open = 1
PolarityOutput_2 RW Always ENUM Active Close = 0
Active Open = 1
PixelFormat RW N.conn ENUM Bayer Raw8 = 17301513
Bayer Raw10 = 17825805
RGB 32-bit = 35651607
UYVY = 34603039
( 2166358018 w/driver 1.30 only )
YUY2 = 2166358018
( 34603039 w/driver 1.30 only )
Power-upConfig RW N.acq ENUM Factory Default = 0
Camera Configuration 1 = 1
TimestampResetSource RW Always ENUM Off = 0
Input 1 = 1
Input 2 = 2
TimestampCounter RW Always ENUM Internal Clock (1µs resolution) = 0
Input 1 = 1
Input 2 = 2
End of Readout = 3
SaveCameraConfigurationSelector RW N.conn ENUM Camera Configuration 1 = 1