46 Operational Reference Genie Color Series-GigE Vision Camera
Exposure Controls via Sapera LT or GigE Vision Compliant
Applications
Sapera
Genie Sapera parameters for Exposure Control:
FrameRate = 0.1 Hz up to max. frame rate supported by sensor in current mode of operation.
Only available with Trigger disabled.
ExposureMode = {Programmable = 1, Pulse Controlled = 2}
ExposureTime = Exposure duration in µs
In CamExpert, these parameters are available under “Sensor” tab.
See "
Accessing Features with Sapera++ LT" on page 66.
XML features for Exposure Control:
ExposureMode = {Off = 0, Timed = 1, TriggerWidth = 2, TriggerControlled = 3,
ResetContinuous = 4}
ExposureTimeRaw = Exposure duration in µs
AcquisitionFrameRate = Controls the desired frame rate of the camera in mHz (0.001 Hz). Only
available when trigger is disabled.
AcquisitionFrameCount = Number of frames to be acquired in MultiFrame acquisition mode
AcquisitionMode = {Continuous = 0, SingleFrame = 1, MultiFrame = 2}
AcquisitionStart = Start image capture using currently selected acquistion mode
AcquisitionStop = Stop image capture
AcquisitionAbort = Abort image capture