User`s manual

Genie Color Series-GigE Vision Camera Operational Reference 51
Input Controls via Sapera LT or GigE Vision Compliant Applications
Sapera
Genie Sapera parameters for Trigger Modes and General Inputs:
TriggerDelayToIntegration = Delay in µs from trigger to exposure
TriggerEnable = {FALSE, TRUE}
TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2}
TriggerSoftware = {FALSE, TRUE}
FramesPerTrigger = Frame count 1 to 64k
PolarityInput_x = {Active High = 0, Active Low = 1}
DebounceInput_x = debounce period in µs (from 1 to 255 µs)
See "
Accessing Features with Sapera++ LT" on page 66.
XML features for Trigger Modes and General Inputs:
TriggerMode = {Off = 0, On = 1}
TriggerSelector = (not used)
TriggerSoftware = Generates a software trigger to start the acquisition in software trigger mode
TriggerSource = {Line2 = 1, Software = 2}
TriggerActivation = {LevelLow = 0, LevelHigh = 1}
TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal before
starting exposure
InputLineSelector = Index to general input {input1=0, input2=1}
InputLinePolarity = {Active High = 0, Active Low = 1}
InputLineDebouncingPeriod = debounce period in µs (from 1 to 255 µs)
InputLineValue = Read input line state {low=0, high=1}
Strobe and General Outputs
Genie provides two sets of opto-coupled outputs (see "External Outputs" on page 96). These can be used as a strobe
signal to control lighting or to generate programmable pulses when specific events are generated by the camera.
They can also be set to a static state (close or open) by the application.
See "
12-Pin Hirose Connector Signal Details" on page 93 for connector pinout and electrical information.