User`s manual

56 Operational Reference Genie Color Series-GigE Vision Camera
Pulse On Input 1 or Input 2 Event Modes
The Pulse On Input 1 or Input 2 event modes generate an output signal when the specified input signal is asserted.
Output Control via Sapera LT or GigE Vision Compliant Applications
Sapera
Genie Sapera parameters for Strobe and General Outputs.
See "
Accessing Features with Sapera++ LT" on page 66.
OutputSelectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2, Pulse On:
Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout = 6, Pulse On: End
of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input 1 = 9, Pulse On: Input 2 = 10}
PulseDelayOutput_x = Delay in µs to assert pulse output
PulseDurationOutput_x = Pulse duration in µs
PolarityOutput_x = {Active Close = 0, Active Open = 1}
XML features for Strobe and General Outputs:
OutputLineSelector = Index to select output line {output 1 = 0, output 2 = 1}
OutputLineMode = {SoftwareDriven = 0, EventDriven = 1}
OutputLineEventSource = Event generating output line pulse {StartOfTrigger=0,
StartOfExposure=1, EndOfExposure=2, StartOfReadout=3, EndOfReadout=4,
EndOfAcquisition=5, EventOnInputLine1=6, EventOnInputLine2=7, OverTrigger=8,
OutputLinePulsePolarity = State of output opto-coupler {Active Close = 0, Active Open = 1}
OutputLinePulseDelay = Delay in µs to assert pulse output (range 0 to 64k)
OutputLinePulseDuration = Pulse duration in µs (range 0 to 64k)
OutputLineValue = static output state {Open = 0, Close = 1}