User`s manual
68 • Operational Reference Genie Color Series-GigE Vision Camera
OutputSelectorOutput_2 RW Always ENUM Open = 0
Close = 1
Pulse On: End of Exposure = 3
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10
PolarityInput_1 RW Always ENUM Active High = 0
Active Low = 1
PolarityInput_2 RW Always ENUM Active High = 0
Active Low = 1
PolarityOutput_1 RW Always ENUM Active Close = 0
Active Open = 1
PolarityOutput_2 RW Always ENUM Active Close = 0
Active Open = 1
PixelFormat RW N.conn ENUM Bayer Raw8 = 17301513
RGB 32-bit = 35651607
UYVY = 2166358018
( 34603039 w/driver 1.20 )
YUY2 = 34603039
Power-upConfig RW N.acq ENUM Factory Default = 0
Camera Configuration 1 = 1
TimestampResetSource RW Always ENUM Reset Off = 0
Input 1 = 1
Input 2 = 2
TimestampCounter RW Always ENUM Internal Clock (1µs resolution) = 0
Input 1 = 1
Input 2 = 2
End of Readout = 3
SaveCameraConfigurationSelector RW N.conn ENUM Camera Configuration 1 = 1
LoadCameraConfigurationSelector RW N.conn ENUM Factory Default = 0
Camera Configuration 1 = 1
NetworkConfigurationMode RW N.conn ENUM Automatic = 0
Manual = 1