User`s manual
48 Pantera 1M60 and 1M30 User’s Manual
DALSA 03-032-10033-09
Camera Link Video Timing
Figure 18: Pantera 1M60 and 1M30 Timing (Input and Output Relationships)
tLF
tLVAL
_
LOWtLINE tLVAL
_
LOWtLINEtFL
tREADOUT tOVERHEADtTRANSFER tREADOUT
tFRAME PERIOD
twSYNC
_
INTtwSYNC twSYNC
_
INT
tFRAME PERIOD
twSYNC
1N
STROBE
EXSYNC
FRAME VALID
LINE VALID
DATA
DVAL
Table 15: 1 Output, ECE Mode of Operation
Binning (HxV)
Symbol 1 x 1
2 x 1
4 x 1
8 x 1
1 x 2
2 x 2
4 x 2
8 x 2
1 x 4
2 x 4
4 x 4
8 x 4
1 x 8
2 x 8
4 x 8
8 x 8
twSYNC (min sync pulse,
not SMART SYNC)
100 ns 100 ns 100 ns 100 ns
twSYNC (min sync pulse
in SMART SYNC)
1.3377 ms 1.3377 ms 1.3377 ms 1.3377 ms
TTRANSFER (time
from falling edge of
EXSYNC to start of readout
in SMART SYNC,
pretrigger=0)
1.3377 ms 1.3377 ms 1.3377 ms 1.3377 ms
TREADOUT (frame
readout time, pretrigger=0)
29.978 ms 15.654 ms 8.5952 ms 4.9152 ms
tOVERHEAD (time
after readout before next
EXSYNC)
1.6 μs 1.6 μs 1.6 μs 1.6 μs
TwSYNC_INT (min
integration pulse, not
SMART SYNC)
29.275 μs 30.575 μs 33.575 μs 38.4 μs
TwSYNC_INT (min
integration pulse, in SMART
SYNC)
29.275μs 30.575 μs 33.2 μs 38.0 μs
tFRAME PERIOD
(min frame period)
31.344 ms 17.023 ms 9.9665 ms 4.9152 ms
tFL (time from FVAL to
first LVAL)
3.075 μs 4.375 μs 6.975 μs 11.8 μs
tLINE (LVAL high time)
25.6 μs 25.6 μs 25.6 μs 25.6 μs
IMPORTANT:
This camera uses the
falling
edge of EXSYNC
to trigger line readout,
unlike previous DALSA
cameras, which used the
rising edge.