User`s manual
Linea 2K, 4K, 8K and 16K Camera User's Manual PRELIMINARY 33
Teledyne DALSA 03-032-20206-01
GenICam parameters to set:
I / O Controls > Trigger Mode > On
Camera Control > Exposure Mode > Trigger Width
Warning! When running external line rate and external exposure time, the line rate must not exceed 1 /
(exposure time + 1 µs). Under these conditions the exposure time will become indeterminate and result in
image artefacts. This is not the case when running internal exposure control.
3. External Line Rate, Programmable Exposure Time
In this mode, the line rate is set externally with the falling edge of EXSYNC generating the rising edge of
a programmable exposure time.