User`s manual

Linea 2K, 4K, 8K and 16K Camera User's Manual PRELIMINARY 59
Teledyne DALSA 03-032-20206-01
Transport Layer Feature Descriptions
The following table describes these parameters along with their view attribute and minimum camera
firmware version required. Additionally the firmware column will indicate which parameter is a
member of the DALSA Features Naming Convention (DFNC), verses the GenICam Standard Features
Naming Convention (SFNC not shown).
Display Name
Feature
Description
Device
Version
& View
Restart Camera
DeviceReset
Used to restart the camera, warm
reset
1.00
Beginner
DFNC
XML Major
Version
DeviceManifestXMLMajorVersion
Together with
DeviceManifestXMLMinorVersion
specifies the GenICam™ feature
description XML
file version (RO)
1.00
Beginner
DFNC
XML Minor
Version
DeviceManifestXMLMinorVersion
Together with
DeviceManifestXMLMajorVersion
specifies the GenICam™ feature
description XML
file version (RO)
1.00
Beginner
DFNC
Last GenCP Status
genCPStatus
If a feature read or write fails then
Sapera only
returns that it fails read this
feature to get the
actual reason for the failure
Returns the last error
Reading this feature clears it
1.00
Beginner
DFNC
Refresh GenCP
Status
refreshGenCPStatus
Press to return the current status of
the GenCP
1.00
Beginner
Camera Link
Configuration
ClConfiguration
Base
Medium
Full
Deca (8k and 16k)
Camera Link Output configuration
1.00
Beginner
Camera Link
Configuration
clDeviceClockFrequency
CL77MHz (2k, 4k, and 8k)
CL50MHz (2k, 4k, and 8k)
CL85MHz (16k)
CL66MHz (16k)
Set the camera link clock rate
1.00
Beginner
Tap Geometry
DeviceTapGeometry
(RO)
1.00
Beginner
Acquisition and Transfer Control Category
The Linea Acquisition and Transfer controls, as shown by CamExpert, groups parameters used to
configure the optional acquisition modes of the device. Parameters in gray are read only, either always or