Specifications

GEVA Users Reference405-00024-00
21Rev 02; 9 November 2010
Camera Control & Power Cable
The GEVA provides two 7-pin Molex connectors for Camera I/O signals to control trigger and
receive strobe. 12 Volt power is also available on this connector. There is a 500 mA fusable link in
the 12 Volt supply at each camera connector.
The camera(s) can be triggered through the GEVA I/O. The external trigger(s) would be input
at the 12-pin Trigger/Strobe connector, and output to the cameras through the 7-pin connectors
illustrated in Figure 2 on page 17.
The camera(s) may have a Strobe output, that can be connected to the GEVA through the 7-pin
connectors and output to external lighting control equipment through the 12-pin Trigger/
Strobe connector.
NOTE iNspect and Sherlock assume Genie camera Input2 is the trigger input, and Ge-
nie camera Output2 is the strobe output (when connected to the GEVA’s Camera
I/O ports). If you use CamExpert to create a camera configuration file, make
sure you use Input2 for trigger, and Output2 for strobe.
The optional camera Control and Power cable can be ordered. Refer to the color coding in the
table that follows.
12 pins
Figure 4. Control and Power Cable
Part Number
Cable Length
A-CAB-GEVA-F0
3 meters
A-CAB-GEVA-F1
5 meters
A-CAB-GEVA-F2
10 meters
A-CAB-GEVA-F3
15 meters