Specifications

GEVA Users Reference 405-00024-00
22 Rev 02; 9 November 2010
Camera Port Pinout
7-pin
Molex
GEVA
Label
Color
Camera
Function
Direction
12-Pin
Hirose
1 TRIG White Trigger on IN2+ Camera In, GEVA Out 11
2 STRB Orange Strobe on OUT2+ Camera Out, GEVA In 7
3 CIN1 Green IN1 + Camera In, GEVA Out 6
4 COUT1 Blue OUT1 + Camera Out, GEVA In 4
5 I/O COM Brown – for all I/O 3, 5, 8, 12
6 12V Red +12 Volt Power Camera Power input 2
7 GND Black Power Ground 1
Cameras pins 3, 5, 8, 12 are connected together through the connector shell and grounded by the
brown wire to I/O COM on the Molex connector.
GEVA supplies 12 Volts at 500 mA maximum to each camera connector through a fusable link.
Figure 5. Camera I/O Port Connectors
Alternative Camera Control Options
Another possible configuration would be:
The camera is triggered directly from the part sensor, bypassing the GEVA.
The camera’s strobe output is connected directly to the lighting equipment, bypassing the
GEVA.
For this case, DALSA offers an optional DCI-100 DALSA Camera Interface module for con-
necting the camera signals to terminal block connectors. A Control and Power cable with 15-pin
DSUB is used to connect the Cameras to the DCI-100. The Camera Power and I/O connectors on
the GEVA would not be used for the strobe and trigger signals when the DCI-100 is in use. Only
the GigE data ports would be used.