Specifications
GEVA User’s Reference 405-00024-00
22 Rev 02; 9 November 2010
Camera Port Pinout
7-pin
Molex
GEVA
Label
Color
Camera
Function
Direction
12-Pin
Hirose
1 TRIG White Trigger on IN2+ Camera In, GEVA Out 11
2 STRB Orange Strobe on OUT2+ Camera Out, GEVA In 7
3 CIN1 Green IN1 + Camera In, GEVA Out 6
4 COUT1 Blue OUT1 + Camera Out, GEVA In 4
5 I/O COM Brown – for all I/O 3, 5, 8, 12
6 12V Red +12 Volt Power Camera Power input 2
7 GND Black Power Ground 1
Cameras pins 3, 5, 8, 12 are connected together through the connector shell and grounded by the
brown wire to I/O COM on the Molex connector.
GEVA supplies 12 Volts at 500 mA maximum to each camera connector through a fusable link.
Figure 5. Camera I/O Port Connectors
Alternative Camera Control Options
Another possible configuration would be:
• The camera is triggered directly from the part sensor, bypassing the GEVA.
• The camera’s strobe output is connected directly to the lighting equipment, bypassing the
GEVA.
For this case, DALSA offers an optional DCI-100 DALSA Camera Interface module for con-
necting the camera signals to terminal block connectors. A Control and Power cable with 15-pin
DSUB is used to connect the Cameras to the DCI-100. The Camera Power and I/O connectors on
the GEVA would not be used for the strobe and trigger signals when the DCI-100 is in use. Only
the GigE data ports would be used.