Specifications
GEVA User’s Reference405-00024-00
27Rev 02; 9 November 2010
Triggers and Strobes
Trigger/Strobe Connector Definitions
Pin # Label Definition Direction
1 TRIG1 IN Trigger 1 input for Camera 1 GEVA Input
2 TRIG1 COM Common for Trigger 1
3 TRIG2 IN Trigger 2 input for Camera 2 GEVA Input
4 TRIG2 COM Common for Trigger 2
5 STRB1 OUT Strobe 1 output from Camera 1 GEVA Output
6 STRB1 COM Common for Strobe 1
7 STRB2 OUT Strobe 2 input for Camera 2 GEVA Output
8 STRB2 COM Common for Strobe 2
9 12V OUT 12 Volt DC output (500 mA @ 20C)
10 PWR GND Ground for 12 Volts & 5 Volts
11 5V OUT 5 Volt DC output (500 mA @20C)
12 PWR GND Ground for 12 Volts & 5 Volts
Pins 10 and 12 are internally connected.
Strobe output current limited by a fusable link on each output. 125 mA @ 20
°C, 50 mA @
85
°C.
Figure 11. Trigger/Strobe/Power Connector