Specifications
GEVA User’s Reference405-00024-00
37Rev 02; 9 November 2010
d. Right-click in the Image Window, and select a camera. If there are no camera selections
available, the Sapera LT driver did not load correctly.
e. Verify that the lens aperture is not closed.
f. Verify that the inspection area (meaning the area that the camera is viewing) is correctly
illuminated.
g. The default trigger threshold is 12 Volts. A 5 Volt signal will not trigger the camera.
3. You have launched iNspect but you do not see an image on the display.
a. Verify the acquisition heartbeat (LED1) is flashing. If it is not, a connection problem is
likely. Verify the cables again.
b. Verify that the lens aperture is not closed.
c. Verify that the inspection area (meaning the area that the camera is viewing) is correctly
illuminated.
d. Verify that the camera and camera port match. The cameras cannot be swapped between
the two ports once their IP Addresses are configured.
e. Verify that all cameras are successfully configured and available, by hovering over the
camera icon in the System tray (by the time display in the lower right corner).
f. Verify the Camera Selector has “GigE camera” selected. Installing a new software ver-
sion defaults to the analog cameras. Click the bubble beside GigE, then click the “Set”
button at the bottom of the Camera Configurator window.
4. Your iNspect Solution file does not load. There are no measurements displayed.
If the camera type used in the saved solution does not match the current attached camera, the solu-
tion will not load. iNspect will start a New Solution.
a. Use the Report Generator utility to create a report of your Solution file. This will specify
the cameras in use when the Solution was created.
Software
There are several software packages that make the GEVA operate with the Genie cameras and
application programs. This section attempts to show how these relate and depend on each other.
VA-Genie Camera Setup
• Configures the Genie camera(s) with fixed IP Addresses compatible with the two camera ports
on the GEVA. This action is performed the first time this utility is run after a new Genie camera
is connected. After that, opening this utility verifies the camera addresses are compatible with
the ports they are connected to. Fixed addresses are necessary for iNspect.