Specifications

GEVA Users Reference 405-00024-00
38 Rev 02; 9 November 2010
GEVA I/O drivers. Configures the connection of trigger inputs and strobe outputs from the
12-pin Trigger/Strobe Connector to the two 7-pin Camera power and I/O connectors. For Sap-
era LT and Sherlock, the driver default (no configuration file) is 2 separate triggers, and strobe
outputs enabled. You can make changes and save them to a file for use with Sherlock. Example
files are included on the GEVA. iNspect has its own separate configuration of the GEVA I/O.
DCI-100 I/O drivers. Configures the programmable logic thresholds on the DCI-100 Module,
through the GEVA or PC serial port. The DCI-100 provides a way to connect camera power
and I/O, separate from the GEVA camera power and I/O connectors.
Acquisition driver for the iNspect application. Cameras are ordered by IP Address when using
the generic configuration file. Cameras are ordered by their Serial Number when using a cus-
tom configuration file, as described in Appendix D.
Acquire and display images. The default camera settings of this program are temporarily writ-
ten to the camera, to allow display in this utility. The camera settings in this program are not
used by the other application programs. Note: Changing the Camera Name in this program
may make the camera inaccessible to the Sherlock and SaperaLT software.
Sapera CamExpert
Change camera configuration settings, such as exposure time, white balance, gain, color out-
put format. Gain and exposure time can also be changed from Sherlock and iNspect.
Save camera settings to the camera memory or a configuration file. You can configure the cam-
era to load either your saved settings, or the factory settings, at power up. The preferred method
is to save your settings to both
the camera and a configuration file. Sherlock can load a configu-
ration file at startup. If multiple configurations are needed, you can save them to camera con-
figuration files. Several example configuration files are included on the GEVA.
Acquire and display images. Changes to the camera settings are temporary, unless saved to the
camera memory or to a configuration file.
SaperaLT Runtime
Acquisition utility for the Sherlock software. Sapera LT is used with the drivers in the Genie
Framework.
Genie Framework
Genie camera acquisition drivers for the SaperaLT and Sherlock software. Genie camera firm-
ware update utility. A System tray icon provides status on the Genie camera connections.
(available, unavailable, disconnected).