Specifications

GEVA Users Reference405-00024-00
41Rev 02; 9 November 2010
Camera Data Connectors
The GigE camera data ports are standard Ethernet RJ-45 8-pin male connectors, located on the
front panel. Camera Port One is assigned a Static IP Address 10.1.64.5 and Camera Port Two is
assigned a Static IP Address 10.1.128.7. Both ports use the Subnet Mask 255.255.192.0 standard
for a 10.x.x.x address.
The VA-Genie Camera Setup program configures the cameras for compatible Static addresses.
The Ethernet ports are also configured for Jumbo Frames and maximum Receive Descriptors (as
described in the Genie Camera Manual).
Camera Port 1 is defined in Windows as PCI Bus 4 Device 0. Camera Port 2 is defined in Win-
dows as PCI Bus 3 Device 0. This information may be needed if you must install a custom hard-
ware driver.
Ethernet Pinout
Pin Name Description
1 BI_DA+ Bi-directional pair A +
2 BI_DA– Bi-directional pair A –
3 BI_DB+ Bi-directional pair B +
4 BI_DC+ Bi-directional pair C +
5 BI_DC– Bi-directional pair C –
6 BI_DB– Bi-directional pair B –
7 BI_DD+ Bi-directional pair C +
8 BI_DD– Bi-directional pair C +
Power Connector
The GEVA is powered from an external supply that connects to the 3-pin molex connector on the
rear panel. The power requirements are:
+24 V +/–10% @ 2.5 A maximum or 60W.
Power Connector Pinout
Pin Name Direction Description
1 Earth not connected
2 GND Ground
3 24V Input DC Power +24 Volts
A power cable (A-CAB-NSII-PWR), with open leads on one end and a mating connector plug on
the other, is shipped standard with the product.