Figure 43. Sapera Camera Acquisition Wizard
NOTE The Wizard attempts to acquire or attach to all cameras discovered on a net-
work. If you have multiple Vision Appliances and multiple cameras connected
on a common “neighborhood” (for example an ethernet PLC controlling the
cameras) the wizard will fail to open if visible cameras are already in use by
other appliances. No error message is given in this case.
Sherlock also uses the IFC driver and a VAGenie Setup configuration file to define the behavior
of the GEVA I/O Connectors. The file \Sherlock\Drivers\IFCDrv.ini defines which I/O Configu-