Specifications
VA6x User’s Reference405-00022-00
25Rev 06; 7 April 2011
Status LEDs and RESET Switch
The Vision Appliance provides 7 LEDs on the front panel, as visual health and status indicators
(shown in Figure 9).
Amber
Amber
Amber
Reset Switch
Red
Yellow
Green
Blue – Power
LED0
LED1
LED2
Application
Camera
Switch Solution
LED3Reject
Recycle
Pass
LED4
LED5
Figure 9. Front Panel Status LEDs and Reset Switch
The Reset button, when depressed, will initiate a system reset/reboot. The button is recessed in
the front panel to prevent accidental contact.
iNspect & iLabel Function
As the iNspect or iLabel application opens, two of the LEDs start flashing. These represent “ap-
plication” and “camera” health. The application “heartbeat” has a 2 second cycle, at 50% duty.
The camera “heartbeat” rate is dependent upon the type of camera and external event time or line
speed, and can be rapidly flashing, or may seem to be constantly on.
The other LED indicators represent “switch solution command” and inspection results (Pass/Re-
cycle/Reject). In the iNspect and iLabel applications, the inspection results are updated with ev-
ery inspection and visually indicate the state of the outputs on the I/O connector. The inspection
results LEDs are latched after a decision, and stay latched until the next decision is available.
Sherlock Function
In Sherlock, all 6 LEDs are under your inspection program control. There are no predefined func-
tions to the LEDs in Sherlock. The LEDs are available in Sherlock as Digital I/O output channels
8 through 13.
LED
Sherlock Digital Output LED Sherlock Digital Output
LED0 amber Channel 8 LED3 red Channel 11
LED1 amber Channel 9 LED4 yellow Channel 12
LED2 amber Channel 10 LED5 green Channel 13