Specifications
VA6x User’s Reference405-00022-00
35Rev 06; 7 April 2011
APPENDIX A
CONNECTORS AND PINOUTS
This section provides the connector pinout information for each of the VA61 external interfaces.
Camera Power and Control Connectors
Camera image data is carried through RJ45 Ethernet connectors. Camera control signals and
power are available on two DB15 connectors. The location and pinout for the D-Sub connectors
are shown below. Each D-Sub cable can supply up to 0.5 A at +12 Volts from chassis power.
Pin 1
Figure 14. Camera Power and I/O Connectors
Camera Control Pinout
Pin number Description Direction
1, 2, 3 Not Connected
4 Camera Input 2 – Out of VA61
5, 10 Power Ground
6 Camera Output 2 – In to VA61
7 Camera Output 1 – no connection
8 Camera Input 1 – no connection
9 Camera Input 2 + (trigger) Out of VA61
12 Camera Output 2 + (strobe) In to VA61
13 Camera Output 1 + no connection
14 Camera Input 1 + no connection
15 +12 Volts (0.5A)