User`s manual

Preliminary
Genie Monochrome Series-GigE Vision Camera Technical Specifications 93
External Outputs
Programmable output mode such as strobe, event notification, etc. (see "Output Control via
Sapera LT or GenICam Applications" on page 56).
OUT+
OUT-
Genie
side
User
side
Hirose-12
Connector
ins
NEC PS2805-1
OUT
680
75
The opto-coupler is typically a NEC PS2805-1 with the following characteristics.
Output Electrical Parameter Description Value
Maximum voltage difference 13 V
Maximum current through opto-coupler 12mA
Minimum output pulse width 100 us
Maximum switch closure transition time 12 µs
Maximum switch open transition time 40 µs