Genie Monochrome Series-GigE Vision Camera Operational Reference 45
External Trigger Level-controlled Exposure
Also known as “Pulse Width Control” exposure. See the timing diagram below.
The external trigger edge initiates the exposure process. The active external trigger edge can be
selected as either the low-high or high-low transition.
No delay from active trigger edge to start of exposure.
Exposure is stopped by the opposite edge on the trigger signal. Therefore the exposure time is
defined by the trigger pulse duration.
Supports
Reset Mode trigger timing only.
External Trigger Level-controlled Exposure Timing
Exposure Controls via Sapera LT or GenICam Applications
Genie Sapera parameters for Exposure Control:
FrameRate = 0.1 Hz up to max. frame rate supported by sensor in current mode of
operation. Only available with Trigger disabled.
ExposureMode = {Programmable = 1, Pulse Controlled = 2}
ExposureTime = Exposure duration in µs