User`s manual
Preliminary
48 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Synchronization Mode via Sapera LT or GenICam Applications
Genie Sapera parameters for Synchronization Mode:
ExposureAlignment = {Synchronous = 0, Reset = 1}
In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure
Control” dialog box.
GenICam features for Synchronization Mode:
SensorSynchronization = {Synchronous = 0, Reset = 1}
CamExpert I/O Controls Dialog
CamExpert groups the Genie I/O Controls Parameters in one group. These parameters allow
configuring the Genie inputs and outputs for type of signal and signal polarity. The screen capture
below shows the CamExpert I/O parameters dialog and is followed by a descriptive overview.
Detailed information on inputs and outputs follow this section.
Parameter Description
Trigger Enables or disables the Genie camera trigger.
Trigger Source Specifies the trigger source. Possible values are Software, Input 1, or Input 2.
Note that this field is only available when the Trigger parameter is Enabled.
Trigger Frame Count Set the number of frames acquired per trigger.
Input Settings
Click on Setting to open the Input Settings dialog box, which allows you to specify
the trigger input settings. For more information, see "
General Inputs: Settings Via
CamExpert" on page 49.
Output Settings
Click on Setting to open the Output Settings dialog box, which allows you to
specify the trigger output settings. For more information, see "
General Outputs:
Settings via CamExpert" on page 51.
For more information on triggers, see "General Inputs" on page 49.