User`s manual

Preliminary
50 Operational Reference Genie Monochrome Series-GigE Vision Camera
Input Controls via Sapera LT or GenICam Applications
Genie Sapera parameters for Trigger Modes and General Inputs:
TriggerDelayToIntegration = Delay in µs from trigger to exposure
TriggerEnable = {FALSE, TRUE}
TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2}
TriggerSoftware = {FALSE, TRUE}
PolarityInput_x = {Active High = 0, Active Low = 1}
DebounceInput_x = debouncing period in µs (from 1 to 255 µs)
GenICam features for Trigger Modes and General Inputs:
TriggerMode = {Off = 0, On = 1}
TriggerSoftware = Generates a software trigger to start the acquisition in software
trigger mode
TriggerSource = {Line2 = 1, Software = 2}
TriggerActivation = {LevelLow = 0, LevelHigh = 1}
TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal
before starting exposure