User`s manual
Preliminary
52 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Open and Close Output Settings
You can open and close the output circuit using software rather than hardware events, to control
external devices. To control the output setting with Sapera LT see "
Output Control via Sapera LT or
GenICam Applications" on page 56.
Strobe On Start of Exposure Event Mode
The Strobe On Start of Exposure event mode is used when controlling a strobe light using the Genie
output pin. The exposure delay parameter is specified using the Sensor Parameters tab Exposure
Control setting.
For Synchronous mode, the exposure start timing is aligned to the line period of the sensor. This can
delay the start of exposure by an amount of up to 31.77µs for the Genie M640. For more information
on exposure synchronous time see "
Exposure Controls" on page 42.