User`s manual
Preliminary
56 • Operational Reference Genie Monochrome Series-GigE Vision Camera
Output Control via Sapera LT or GenICam Applications
Genie Sapera parameters for Strobe and General Outputs.
Use the SapAcqDevice::SetFeatureValue function.
OutputSelectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2,
Pulse On: Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout
= 6, Pulse On: End of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input
1 = 9, Pulse On: Input 2 = 10}
PulseDelayOutput_x = Delay in µs to assert pulse output
PulseDurationOutput_x = Pulse duration in µs
PolarityOutput_x = {Active Close = 0, Active Open = 1}
GenICam features for Strobe and General Outputs:
Not supported in current version
Genie Processing Features
The Genie monochrome series of cameras support a number of functions to enhance acquisitions or
perform real time processing. Functions can be combined to solve specific imaging situations. The
user can enable and evaluate each operation by using CamExpert.
Lookup Table (LUT)
The Genie camera includes a user programmable LUT as a component of its embedded processing
features. The LUT is used for operations such as gamma adjustments, invert and threshold processes.
CamExpert has a number of built in LUT operations for the user to explore (see "
CamExpert LUT
Controls" on page 87).
For monochrome sensors, the LUT table is a single 8-bit LUT (8-bit in, 8-bit out) as illustrated in the
following figure. Pixel data when read out of the sensor is passed through the LUT memory array,
where the new programmed pixel value is then passed to the Genie output circuit. The LUT data table
is stored along with other parameters with the user configuration function (see "
Power-up
Configuration" on page 30).