User`s manual
70 Operational Reference Genie Monochrome Series-GigE Vision Camera
Feature Event Name
(case sensitive strings)
Description
Start of Trigger Trigger is valid based on the programmed trigger parameters
Start of Exposure Exposure has started
End of Exposure Exposure is complete
End of Acquisition Transfer of image is terminated from camera.
This does not mean that the host PC has received all data packets.
End of Readout End of image readout from sensor to onboard buffer
Feature Value Changed Parameter value is changed
Feature Info Changed One or more parameter components has changed, such as a maximum or minimum
range limit, access mode, enumeration element, or parameter value.
Invalid Trigger Trigger event (software or external) was invalid
Input Event 0 External Input # 1 has received a valid signal
Input Event 1 External Input # 2 has received a valid signal
Output Event 0 External Output # 1 has changed state
Output Event 1 External Output # 2 has changed state
Event Selection via GigE Vision Compliant Applications
XML features for Events:
EventSelector = {None = 0, FrameTrigger = 2, ExposureStart = 3, ExposureEnd = 4,
InvalidFRameTrigger = 0x9008, AcquisitionEnd = 0x9003}
EventNotification = {Off = 0, GigEVisionEvent = 1}
Event_FrameTrigger_TimeStamp = Generate an Event on a frame trigger
Event_ExposureStart_TimeStamp = Event on exposure start
Event_ExposureEnd_TimeStamp = Event on exposure end
Event_InvalidTrigger_TimeStamp = Event when invalid trigger received